Enter your keyword

How Long does the UV30 Pump last?

09-03-2017

How Long does the UV30 Pump last?

UV30

The hour-meter displays more than 124.000 hours of operation. This value corresponds to 92% of the time since the pump’s installation in 2000. The Air End of this unit has never needed to be overhauled or replaced so far. The entire machine had been well maintained with original spare parts, namely the cooling fluid and the three filters for oil, oil-separation and inlet air. This is an excellent result, compared to the former screw vacuum pumps used by the customer, which required repeated overhauling of the screw Air End every 40.000 hours. As a consequence, the customer chose to further invest in Rotary Vane Technology and upgrade its system with a new UV50 vacuum pump.